Wind Turbine Common Failure & Handling
Fault Symptom |
Reason |
Method of Handling |
Blower fan runs down. |
1. The accumulator is fully charged 2. The controller switch is not switched on. 3. Bad wiring 4. The fuse of the controller is fused. 5. Serious overdischarge |
1. Normal 2. Turn on the controller switch. 3. Eliminate wiring fault. 4. Replace the controller fuse. 5. Repair or replace the accumulator |
Blower fan shakes. |
1. The bolt becomes loose. 2. The bolt becomes loose. 3. Ice is formed on the blade or foreign matter adheres to the blade. |
1. Level the tensioning steel cable. 2. Examine the tightened bolts. 3. Clear the attachment on the blade. |
It veers to the wind ineffectively |
1. The veer bearing is too dirty with grease or the bearing is damaged. 2. The slip ring is locked. |
1. Clear and repair the veer bearing. 2. Check the contact condition of brush and slip ring. |
Output voltage is too low. |
1. Bad wiring 2. The wire is too long and the wire size is to thin. 3. The wind wheel creeps. 4. Slip ring and brush are bad contacted. |
1. Check cable terminals of each point. 2. Replace with applicable wire. 3. Fix the wind wheel to the motor shaft. 4. Check the contact condition of brush and slip ring. |
Accumulator is lack of power all along. |
1. The output voltage of the set is too low. 2. The connector of accumulator is rusted. 3. The accumulator is broken down. |
1. Check and treat it according the above column. 2. Clear the connector. 3. Repair and replace accumulator |
It cannot stop automatically. |
1. The output cable of the motor is wired badly. 2. The controller is broken down. |
1. Check the connection from the output line of the motor to the input
line of the controller. 2. Contact the dealer for maintenance |